We report the perspective development at TRINITI of the UV and IR lasers. Results of experimental investigations of the following lasers are presented: ArF laser (λ = 193 nm) with average power up to 100 W and high repetition rate, CO-laser (λ = 5.3 ÷ 6.6 μm) with average power up to 50W and CO2-laser (λ = 10.6 μm) with laser pulse duration 3 - 5 μs and energy per pulse ~5J.

Paper Details

Date Published: 29 July 2004
PDF: 6 pages
Proc. SPIE 5486, ALT'03 International Conference on Advanced Laser Technologies: Biomedical Optics, (29 July 2004); doi: 10.1117/12.572448