Measurements of cross-sensitivity to contaminant gases using a highly selective, optical-fiber-remoted methane sensor based on correlation spectroscopy
Author(s): Henry O. Edwards; John P. Dakin
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

An optical-fiber methane sensor that uses a correlation technique based on pressure modulation is reviewed. The sensitivity to methane was measured and the cross-sensitivity to a number of contaminant gases, such as ethane, has been determined. The performance of this system is compared with conventional gas-absorption measurement techniques in order to determine a figure of merit for the selectivity improvement.

Paper Details

Date Published: 1 March 1992
PDF: 8 pages
Proc. SPIE 1587, Chemical, Biochemical, and Environmental Fiber Sensors III, (1 March 1992); doi: 10.1117/12.56551