Share Email Print
cover

Proceedings Paper

Thin glass mirrors for the Pierre Auger project
Author(s): Petr Schovanek; Miroslav Palatka; Miroslav Hrabovsky; Martin Vlcek
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Joint Laboratory of Optics produce mirrors for fluorescence optical detector of the Pierre Auger Project placed in Argentina. We want resume our manufacturing quality measurements and compare first two made telescopes with the prototype one. We measure radius of curvature, spot size and reflectivity in ultra-violet region.

Paper Details

Date Published: 21 November 2003
PDF: 5 pages
Proc. SPIE 5259, 13th Polish-Czech-Slovak Conference on Wave and Quantum Aspects of Contemporary Optics, (21 November 2003); doi: 10.1117/12.545133
Show Author Affiliations
Petr Schovanek, Palacky Univ. (Czech Republic)
Miroslav Palatka, Palacky Univ. (Czech Republic)
Miroslav Hrabovsky, Palacky Univ. (Czech Republic)
Martin Vlcek, Palacky Univ. (Czech Republic)


Published in SPIE Proceedings Vol. 5259:
13th Polish-Czech-Slovak Conference on Wave and Quantum Aspects of Contemporary Optics
Jerzy Nowak; Marek Zajac; Jan Masajada, Editor(s)

© SPIE. Terms of Use