Paper Abstract

A four-alternative forced-choice experiment was conducted to investigate the relative impact of detector noise and anatomical structure on detection of subtle lung nodules. Sets of four independent backgrounds from each of three regions (heart, ribs, and lung field between the ribs) were derived from a very low-noise chest-phantom capture. Simulated nodules of varying contrast and fixed diameter (10 mm) were digitally added to the centers of selected background images. Subsequently, signal-dependent noise was introduced to simulate amorphous selenium radiographic detector performance at typical 80, 200, 400, 800, or higher speed class exposures. Series of four nodule contrasts each were empirically selected to yield comparable ranges of detectability index (d') for each background type and exposure level. Thirty-six observers with imaging expertise performed the nodule detection task, for which the signal and location were known exactly. Equally detectable nodule contrasts for each background type and exposure level were computed and their squares plotted against detector noise variance. The intercepts and slopes of the linear regressions increased in the order of lung, heart, and ribs, correlating with apparent anatomical structural complexity. The regression results imply that the effect of anatomical structure dominated that of capture device noise at clinically relevant exposures and beyond.

Paper Details

Date Published: 4 May 2004
PDF: 12 pages
Proc. SPIE 5372, Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment, (4 May 2004); doi: 10.1117/12.536733
Show Author Affiliations
Brian W. Keelan, Eastman Kodak Co. (United States)
Karin Topfer, Eastman Kodak Co. (United States)
John Yorkston, Eastman Kodak Co. (United States)
William J Sehnert, Eastman Kodak Co. (United States)
Jacquelyn S Ellinwood, Eastman Kodak Co. (United States)


Published in SPIE Proceedings Vol. 5372:
Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment
Dev P. Chakraborty; Miguel P. Eckstein, Editor(s)

© SPIE. Terms of Use
Back to Top