Share Email Print
cover

Proceedings Paper

Flat-panel-detector-based cone-beam CT imaging: preliminary system evaluation
Author(s): Ruola Ning; David L. Conover; Yong Yu; Xianghua Lu
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The purpose of this study was to perform a preliminary evaluation of a newly constructed s flat panel detector (FPD)-based system for cone beam CT imaging applications. A prototype flat-panel detector-based cone beam CT imaging system has been designed and constructed by modifying a GE HiSpeed Advantage CT scanner. The prototype consisted of a modified GE CT HiSpeed Advantage CT gantry, an x-ray tube, an 19.5 x 24.4 cm Varian Paxscan 2520 real time flat-panel detector mounted on the gantry, a CT table and an on-gantry PC to control image acquisition. Another PC workstation serving as an operating console controlled the CT gantry and CT table, and sent trigger pulses to dedicated electronic interface modules to control radiographic exposure and to initiate data acquisition. Captured image data sets were first stored in an on-gantry computer and then downloaded from the on-gantry PC to the operating console for high-speed 3D image reconstruction. During data acquisition, the x-ray tube and the FPD can be rotated on the gantry over Nx360 degrees due to integrated slip ring technology. With a single scan, this device was able to acquire up to 288 two-dimensional projections (960 x 768 x 16 bits) for direct 3D reconstruction within 9.6 seconds. This system was used for a series of preliminary phantom studies. Using the continuous scan mode of the scanner, 288 projections were acquired for all volume scans. Direct 3D reconstructions were obtained to evaluate the system for cone beam CT for lung imaging applications. The preliminary results indicate that the newly built flat panel detector-based cone beam CT scanner worked as expected.

Paper Details

Date Published: 6 May 2004
PDF: 5 pages
Proc. SPIE 5368, Medical Imaging 2004: Physics of Medical Imaging, (6 May 2004); doi: 10.1117/12.536221
Show Author Affiliations
Ruola Ning, Univ. of Rochester Medical Ctr. (United States)
David L. Conover, Univ. of Rochester Medical Ctr. (United States)
Yong Yu, Univ. of Rochester Medical Ctr. (United States)
Xianghua Lu, Univ. of Rochester Medical Ctr. (United States)


Published in SPIE Proceedings Vol. 5368:
Medical Imaging 2004: Physics of Medical Imaging
Martin J. Yaffe; Michael J. Flynn, Editor(s)

© SPIE. Terms of Use