Share Email Print
cover

Proceedings Paper

Assessment of visual quality and spatial accuracy of fast anisotropic diffusion and scan conversion algorithms for real-time three-dimensional spherical ultrasound
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Three-dimensional ultrasound machines based on matrix phased-array transducers are gaining predominance for real-time dynamic screening in cardiac and obstetric practice. These transducers array acquire three-dimensional data in spherical coordinates along lines tiled in azimuth and elevation angles at incremental depth. This study aims at evaluating fast filtering and scan conversion algorithms applied in the spherical domain prior to visualization into Cartesian coordinates for visual quality and spatial measurement accuracy. Fast 3d scan conversion algorithms were implemented and with different order interpolation kernels. Downsizing and smoothing of sampling artifacts were integrated in the scan conversion process. In addition, a denoising scheme for spherical coordinate data with 3d anisotropic diffusion was implemented and applied prior to scan conversion to improve image quality. Reconstruction results under different parameter settings, such as different interpolation kernels, scaling factor, smoothing options, and denoising, are reported. Image quality was evaluated on several data sets via visual inspections and measurements of cylinder objects dimensions. Error measurements of the cylinder's radius, reported in this paper, show that the proposed fast scan conversion algorithm can correctly reconstruct three-dimensional ultrasound in Cartesian coordinates under tuned parameter settings. Denoising via three-dimensional anisotropic diffusion was able to greatly improve the quality of resampled data without affecting the accuracy of spatial information after the modification of the introduction of a variable gradient threshold parameter.

Paper Details

Date Published: 28 April 2004
PDF: 12 pages
Proc. SPIE 5373, Medical Imaging 2004: Ultrasonic Imaging and Signal Processing, (28 April 2004); doi: 10.1117/12.535813
Show Author Affiliations
Qi Duan, Columbia Univ. (United States)
Elsa D. Angelini, Columbia Univ. (United States)
Andrew Laine, Columbia Univ. (United States)


Published in SPIE Proceedings Vol. 5373:
Medical Imaging 2004: Ultrasonic Imaging and Signal Processing
William F. Walker; Stanislav Y. Emelianov, Editor(s)

© SPIE. Terms of Use
Back to Top