Share Email Print
cover

Proceedings Paper

Dynamic range measurements on streak image tubes with internal and external image amplification
Author(s): R. T. Eagleton; Steven F. James
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Dynamic range measurements have been made on EEV P8307 Photochron II type) streak image tubes with both internal microchannel plate (MCP), and externally coupled wafer intensifier tube, image amplification. When arranged for equal radiant gain at 560 nm, both configurations showed comparable dynamic range of approximately 1100 and approximately 2900 for 30 ps and 100 ps duration (fwhm) input pulses respectively. The variation in dynamic range with photocathode current density was also measured and the results compared to a computational model based on Coulomb repulsion in the image tube. Experimental data are compared to the model and shown to be in moderate agreement.

Paper Details

Date Published: 1 August 2003
PDF: 6 pages
Proc. SPIE 4948, 25th International Congress on High-Speed Photography and Photonics, (1 August 2003); doi: 10.1117/12.516953
Show Author Affiliations
R. T. Eagleton, AWE Aldermaston (United Kingdom)
Steven F. James, AWE Aldermaston (United Kingdom)


Published in SPIE Proceedings Vol. 4948:
25th International Congress on High-Speed Photography and Photonics
Claude Cavailler; Graham P. Haddleton; Manfred Hugenschmidt, Editor(s)

© SPIE. Terms of Use