Share Email Print
cover

Proceedings Paper

Comparison between visible/NIR spectroscopy and hyperspectral imaging for detecting surface contaminants on poultry carcasses
Author(s): Kurt C. Lawrence; William R. Windham; Bosoon Park; Douglas P. Smith; Gavin H. Poole
Format Member Price Non-Member Price
PDF $17.00 $21.00

Paper Abstract

The U. S. Department of Agriculture, Agricultural Research Service has been developing a method and system to detect fecal contamination on processed poultry carcasses with hyperspectral and multispectral imaging systems. The patented method utilizes a three step approach to contaminant detection. Spectra of homogenous samples of feces, ingesta (undigested food particles), and skin were first collected. Then those spectra were evaluated with multivariate analysis techniques to identify significant wavelength regions for further analysis. Hyperspectral data were then collected on contaminated poultry carcasses and information learned from the spectroscopic data was used to aide in hyperspectral data analysis. Finally, the results of the hyperspectral data were used to identify a few optimum wavelengths for use in a real-time multispectral imaging system. In this work, two techniques for developing spectral datasets and algorithms for classifying surface contaminants on poultry carcasses were explored. The first consisted of a scanning monochrometer that measured the average spectra of uncontaminated breast skin and fecal and ingesta contaminants. The second technique used regions of interest (ROI) from a hyperspectral image to collect spatially averaged spectra. Comparison of the spectra from each instrument showed variations in the spectra collected from similar samples. There was an offset of absorption values between the two instruments and the hyperspectral imaging system had better resolution at higher absorption wavelengths. Although both systems were calibrated prior to measuring, there was also a slight shift in absorption peaks between the two systems. Both techniques were able to classify contaminated skin from uncontaminated skin in a full cross-validated test set with better than 99% accuracy. However, when the classification model developed from the monochrometer spectra was applied to whole-carcass hyperspectral images, numerous common carcass features, such as exposed meat and wing-shadowed skin, were wrongly identified as false positives. Since spectra of entire poultry carcasses were available in the original hyperspectral dataset, the hyperspectral ROI technique allowed researchers to easily add the spectra of these false positives to the calibration dataset. New partial least squares regression models with meat and skin shadow spectra resulted in different principal component loadings and improved classification models. The classification model with the combined ROI spectra from skin, feces, ingesta, meat, and skin shadows gave a classification accuracy of 99.5%. When this model was compared to the original model developed from the monochrometer dataset on a few hyperspectral images of contaminated carcasses, fewer false positives were classified with the hyperspectral ROI model without sacrificing the accuracy of contaminant detection. Further research must be done to fully characterize the accuracy of the model.

Paper Details

Date Published: 30 March 2004
PDF: 8 pages
Proc. SPIE 5271, Monitoring Food Safety, Agriculture, and Plant Health, (30 March 2004); doi: 10.1117/12.516153
Show Author Affiliations
Kurt C. Lawrence, U.S. Dept. of Agriculture (United States)
William R. Windham, U.S. Dept. of Agriculture (United States)
Bosoon Park, U.S. Dept. of Agriculture (United States)
Douglas P. Smith, U.S. Dept. of Agriculture (United States)
Gavin H. Poole, Institute for Technology Development (United States)


Published in SPIE Proceedings Vol. 5271:
Monitoring Food Safety, Agriculture, and Plant Health
George E. Meyer; Yud-Ren Chen; Shu-I Tu; Bent S. Bennedsen; Andre G. Senecal, Editor(s)

© SPIE. Terms of Use
Back to Top