Characterization of mercuric iodide photoconductor for radiographic and fluoroscopic medical imagers
Author(s): Barry N. Breen; Ofer Dagan; Leonid Melekhov; Michael M. Schieber; Haim Gilboa; George Zentai; Larry D. Partain; Raisa Pavlyuchkova; Cesar Proano; Gary F. Virshup
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Photoconductive polycrystalline mercuric iodide deposited on flat panel thin film transistor (TFT) arrays is one of the best candidates for direct digital X-ray detectors for radiographic and fluoroscopic medical imaging. The mercuric iodide is vacuum deposited by Physical Vapor Deposition (PVD). This deposition technology has been scaled up to the 20cmX25cm size required in common medical imaging applications. A TFT array with a pixel pitch of 127 microns is used for these imagers. In addition to successful imager scale up, non-TFT based detectors were developed in order to improve analysis methods of the mercuric iodide photoconductor itself. These substrates consist of an array of palladium or ITO stripes on a glass substrate. Following deposit of the photoconductor, striped bias electrodes are deposited on top of the photoconductor at a 90 degree orientation to the bottom electrodes. These substrates provide more information than was previously available on the dark current and signal uniformity of the mercuric iodide photoconductor without the use of expensive TFT arrays. Mercuric iodide photoconductor thicknesses between 110 microns and 300 microns were tested with beam energy between 40 kVp and 120 kVp utilizing exposure ranges typical for both fluoroscopic and radiographic imaging. Diagnostic quality radiographic and fluoroscopic images at up to 15 pulses per second were demonstrated. Resolution tests on resolution target phantoms were performed and performance close to the theoretical sinc function up to the Nyquist frequency of ~3.9 lp/mm is shown (127 micron pixel pitch).

Paper Details

Date Published: 20 January 2004
PDF: 10 pages
Proc. SPIE 5198, Hard X-Ray and Gamma-Ray Detector Physics V, (20 January 2004); doi: 10.1117/12.510871
Show Author Affiliations
Barry N. Breen, Real Time Radiography, Ltd. (Israel)
Ofer Dagan, Real Time Radiography, Ltd. (Israel)
Leonid Melekhov, Real Time Radiography, Ltd. (Israel)
Michael M. Schieber, Real Time Radiography, Ltd. (Israel)
Haim Gilboa, Real Time Radiography, Ltd. (Israel)
George Zentai, Varian Medical Systems, Inc. (United States)
Larry D. Partain, Varian Medical Systems, Inc. (United States)
Raisa Pavlyuchkova, Varian Medical Systems, Inc. (United States)
Cesar Proano, Varian Medical Systems, Inc. (United States)
Gary F. Virshup, Varian Medical Systems, Inc. (United States)


Published in SPIE Proceedings Vol. 5198:
Hard X-Ray and Gamma-Ray Detector Physics V
Larry A. Franks; Arnold Burger; Ralph B. James; Paul L. Hink, Editor(s)

© SPIE. Terms of Use
Back to Top