Share Email Print
cover

Proceedings Paper

Anode readout for pixellated CZT detectors
Author(s): Tomohiko Narita; Jonathan E. Grindlay; Jaesub Hong; Francis C. Niestemski
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Determination of the photon interaction depth offers numerous advantages for an astronomical hard X-ray telescope. The interaction depth is typically derived from two signals: anode and cathode, or collecting and non-collecting electrodes. We present some preliminary results from our depth sensing detectors using only the anode pixel signals. By examining several anode pixel signals simultaneously, we find that we can estimate the interaction depth, and get sub-pixel 2-D position resolution. We discuss our findings and the requirements for future ASIC development.

Paper Details

Date Published: 3 February 2004
PDF: 6 pages
Proc. SPIE 5165, X-Ray and Gamma-Ray Instrumentation for Astronomy XIII, (3 February 2004); doi: 10.1117/12.506552
Show Author Affiliations
Tomohiko Narita, College of the Holy Cross (United States)
Jonathan E. Grindlay, Harvard-Smithsonian Ctr. for Astrophysics (United States)
Jaesub Hong, Harvard-Smithsonian Ctr. for Astrophysics (United States)
Francis C. Niestemski, College of the Holy Cross (United States)


Published in SPIE Proceedings Vol. 5165:
X-Ray and Gamma-Ray Instrumentation for Astronomy XIII
Kathryn A. Flanagan; Oswald H. W. Siegmund, Editor(s)

© SPIE. Terms of Use