Share Email Print
cover

Proceedings Paper

UCSD high-energy x-ray timing experiment magnetic shield design and test results
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Results are reported from an effort to define a passive magnetic field concept for the High Energy X-ray Timing Experiment (HEXTE), in the interest of reducing the detector-gain variations due to 0.5-1.0-sec timescale magnetic field variations. This will allow a sensitivity of the order of 1 percent of the HEXTE background. While aperture modulation and automatic gain control will minimize effects on timescales of tens of seconds and longer, passive magnetic shielding of the photomultiplier tubes will address 1-sec timescale variations due to aperture motions.

Paper Details

Date Published: 1 October 1991
PDF: 14 pages
Proc. SPIE 1549, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy II, (1 October 1991); doi: 10.1117/12.48333
Show Author Affiliations
Richard E. Rothschild, Univ. of California/San Diego (United States)
Michael R. Pelling, Univ. of California/San Diego (United States)
Paul L. Hink, Univ. of California/San Diego (United States)


Published in SPIE Proceedings Vol. 1549:
EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy II
Oswald H. W. Siegmund; Richard E. Rothschild, Editor(s)