Paper Abstract

This paper presents two non-rigid image registration algorithms: Thirion's Demons method and its spline-based extension, and compares their performance on the task of inter-subject registration of MRI brain images. The methods are designed to be fast and derive their speed from the uncoupling of the correspondence calculation and deformation interpolation procedures, each of which are then amenable to efficient implementation. The evaluation results indicate that this uncoupling does not significantly limit the registration accuracy that can be achieved.

Paper Details

Date Published: 15 May 2003
PDF: 8 pages
Proc. SPIE 5032, Medical Imaging 2003: Image Processing, (15 May 2003); doi: 10.1117/12.481381
Show Author Affiliations
Zhiyong Xie, Univ. of Pennsylvania (United States)
Lydia Ng, Insightful Corporation (United States)
James C. Gee, Univ. of Pennsylvania (United States)


Published in SPIE Proceedings Vol. 5032:
Medical Imaging 2003: Image Processing