Proceedings Paper

Evaluation of reconstruction accuracy of cone beam volume CT breast imaging for different scanning orbits
Author(s): Ruola Ning; Xianghua Lu; Biao Chen; Yong Yu
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Conventional screen film mammography is the most effective tool for the early detection of breast cancer currently available. However, conventional mammography has relatively low sensitivity for detecting small breast cancers (under several millimeters). Specificity and the positive predictive value of mammography remain limited owing to an overlap in the appearance of benign and malignant lesions, and surrounding structure. We propose to address the limitations accompanying conventional mammography by incorporating a cone beam volume CT (CBVCT) reconstruction technique with a recently developed flat panel detector. In this study, we present the results obtained from a computer simulation study and a breast-imaging phantom experimental study to find out the reconstruction accuracy of different cone beam volume scanning orbits for CBVCTBI, and to determine if different partial scan protocols (less than 360°) are appropriate for breast cancer detection. Three types of CBVCTBI scanning orbits were simulated using an uncompressed breast phantom. The reconstruction accuracy was evaluated as a function of different scanning orbits assuming reconstruction with 360° was the gold standard. The results indicate that with 180° plus cone angle orbit, the reconstruction error is below 4% that is in the acceptable range. In addition, a preliminary phantom study using both 360° and 180° plus cone angle orbits, was conducted on the current flat panel detector-based CBVCT prototype scanner. The companion CBVCT reconstruction images of an uncompressed breast-image phantom are presented.

Paper Details

Date Published: 5 June 2003
PDF: 9 pages
Proc. SPIE 5030, Medical Imaging 2003: Physics of Medical Imaging, (5 June 2003); doi: 10.1117/12.480252
Show Author Affiliations
Ruola Ning, Univ. of Rochester Medical Ctr. (United States)
Xianghua Lu, Univ. of Rochester Medical Ctr. (United States)
Biao Chen, Univ. of Rochester Medical Ctr. (United States)
Yong Yu, Univ. of Rochester Medical Ctr. (United States)


Published in SPIE Proceedings Vol. 5030:
Medical Imaging 2003: Physics of Medical Imaging
Martin J. Yaffe; Larry E. Antonuk, Editor(s)

© SPIE. Terms of Use
Back to Top