Share Email Print
cover

Proceedings Paper

Basic performance evaluation of the first model of a four-dimensional CT scanner
Author(s): Shinichiro Mori; Masahiro Endo; Takanori Tsunoo; Susumu Kandatsu; Shuzi Tanada; Hiroshi Aradate; Yasuo Saito; Hiroaki Miyazaki; Kazumasa Sato; Satoshi Matsushita; Masahiro Kusakabe
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We have developed a prototype of 4-dimensional (4D) CT-scanner that employs continuous rotation of cone-beam. Because a cone-beam scan along a circle orbit did not collect a complete set of data to make rigid reconstruction of volume (3D image), it might bring disadvantages or artifacts. To examine effects of the cone-beam data collection on image quality, we have evaluated basic performances of the prototype and compared them to those of a state-of-the-art multi-detector (MD) CT-scanner. As the results image characteristics such as noise, uniformity, high contrast and low contrast detectability of 4D CT were independent of z-coordinate, and comparable to those of MD CT. The transverse spatial resolution of 4D CT was independent of z-coordinate, and showed slightly better performance than that of MD CT, while the longitudinal spatial resolution of 4D CT was the same as the transverse one, and much better than that of MD CT in the present scan conditions. Isotropic resolving power of 0.5mm was achieved for 4D CT. A Feldkamp artifact was observed in distortion measurement though its clinical meaning has not been clarified. Exposure dose measured with CT dose index (CTDI) for 4D CT was comparable to that for MD CT. As a whole our first model of 4D CT-scanner was successful to take a volume data of 10cm long along longitudinal direction in a single rotation scan with comparable image quality and exposure dose to the state-of-the-art MD CT-scanner.

Paper Details

Date Published: 5 June 2003
PDF: 9 pages
Proc. SPIE 5030, Medical Imaging 2003: Physics of Medical Imaging, (5 June 2003); doi: 10.1117/12.480219
Show Author Affiliations
Shinichiro Mori, National Institute of Radiological Sciences (Japan)
Masahiro Endo, National Institute of Radiological Sciences (Japan)
Takanori Tsunoo, National Institute of Radiological Sciences (Japan)
Susumu Kandatsu, National Institute of Radiological Sciences (Japan)
Shuzi Tanada, National Institute of Radiological Sciences (Japan)
Hiroshi Aradate, Toshiba Corp. (Japan)
Yasuo Saito, Toshiba Corp. (Japan)
Hiroaki Miyazaki, Toshiba Corp. (Japan)
Kazumasa Sato, Sony Corp. (Japan)
Satoshi Matsushita, Sony Corp. (Japan)
Masahiro Kusakabe, Fukui Univ. (Japan)


Published in SPIE Proceedings Vol. 5030:
Medical Imaging 2003: Physics of Medical Imaging
Martin J. Yaffe; Larry E. Antonuk, Editor(s)

© SPIE. Terms of Use
Back to Top