Share Email Print
cover

Proceedings Paper

Multimodality vascular imaging phantom for calibration purpose
Author(s): Guy Cloutier; Gilles Soulez; Pierre Teppaz; Salah D. Qanadli; Zhao Qin; Louis-Gilles Durand
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The objective of the project was to design a vascular phantom compatible with X-ray, ultrasound and MRI. Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from the 3D reconstructed images. They also allowed optimizing image fusion and calibration. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, complex realistic geometries of normal and pathological vessels were modeled. The fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRI for 5h of scan. The potential use of the phantom for calibration, rescaling, and fusion of 3D images obtained from the different modalities as well as its use for the evaluation of intra and inter-modality comparative studies of imaging systems were recently demonstrated by our group (results published in SPIE-2003). Endovascular prostheses were also implanted into the lumen of the phantom to evaluate the extent of metallic imaging artifacts (results submitted elsewhere). In conclusion, the phantom can allow accurate calibration of radiological imaging devices and quantitative comparisons of the geometric accuracy of each radiological imaging method tested.

Paper Details

Date Published: 30 May 2003
PDF: 10 pages
Proc. SPIE 5029, Medical Imaging 2003: Visualization, Image-Guided Procedures, and Display, (30 May 2003); doi: 10.1117/12.479577
Show Author Affiliations
Guy Cloutier, Univ. of Montreal (Canada)
Gilles Soulez, Univ. of Montreal (Canada)
Pierre Teppaz, Clinical Research Insitute of Montreal (Canada)
Salah D. Qanadli, Univ. of Montreal (Canada)
Zhao Qin, Univ. of Montreal (Canada)
Clinical Research Insitute of Montreal (Canada)
Louis-Gilles Durand, Clinical Research Insitute of Montreal (Canada)


Published in SPIE Proceedings Vol. 5029:
Medical Imaging 2003: Visualization, Image-Guided Procedures, and Display
Robert L. Galloway, Editor(s)

© SPIE. Terms of Use
Back to Top