Optical Computed Tomography is a useful tool for plasma diagnostics. But in plasma physics, viewing access is very limited, which leads a highly undetermined inversion problem. Two major approaches to this problem are compared in this paper: Maximum Entropy (ME) method and Simultaneous Iterative Reconstruction Technique (SIRT). The results of numerical simulation and experiments illustrate that both two algorithms can yield good qualities of reconstruction with limited views when some prior information has incorporated into calculation. Especially, in the case of two views, with prior information, a good result can even be achieved by ME algorithm.

Paper Details

Date Published: 20 September 2002
PDF: 9 pages
Proc. SPIE 4927, Optical Design and Testing, (20 September 2002); doi: 10.1117/12.471681
Show Author Affiliations
Xiong Wan, Nanchang Institute of Aeronautical Technology (China)
Yiqing Gao, Nanchang Institute of Aeronautical Technology (China)
Shenglin Yu, Nanjing Univ. of Aeronautics and Astronautics (China)