Share Email Print
cover

Proceedings Paper

Calibration method of three-band infrared integrated radiometer
Author(s): Xia Wang; Zhiyun Gao; Jianyong Zhang; Weiqi Jin
Format Member Price Non-Member Price
PDF $17.00 $21.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

A three band infrared integrated radiometer was developed for field measurement. The composition and work theory of the radiometer are described in this paper. The detailed calibration methods are analyzed for extended source and point source, and corresponding measurement results are given. With test data, the experimental results and instrument performance are analyzed in detail, in respect of the equivalent temperature of inter reference blackbody, linearity with target temperature, measurement error of point source and extended source. To lessen the influents of calibration for measurement, the attentive problems in actual calibration of extended source and point source are summarized, and satisfied results are acquired.

Paper Details

Date Published: 20 September 2002
PDF: 6 pages
Proc. SPIE 4927, Optical Design and Testing, (20 September 2002); doi: 10.1117/12.471417
Show Author Affiliations
Xia Wang, Beijing Institute of Technology (China)
Zhiyun Gao, Beijing Institute of Technology (China)
Jianyong Zhang, Beijing Institute of Technology (China)
Weiqi Jin, Beijing Institute of Technology (China)


Published in SPIE Proceedings Vol. 4927:
Optical Design and Testing
Zhicheng Weng; Jose M. Sasian; Yongtian Wang, Editor(s)

© SPIE. Terms of Use
Back to Top