Share Email Print
cover

Proceedings Paper

En-face optical coherence imaging for three-dimensional microscopy
Author(s): Masahiro Akiba; Kin Pui Chan; Naohiro Tanno
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

En-face optical coherence tomography (OCT) employing parallel heterodyne detection technique is demonstrated for three-dimensional microscopy. To enable the use of commercially available CCD cameras as two-dimensional heterodyne detector arrays in OCT imaging, a frequency synchronous detection method is employed. Depth-resolved, full-field images are acquired at 30 Hz video-rate without lateral scanning.

Paper Details

Date Published: 15 May 2002
PDF: 8 pages
Proc. SPIE 4621, Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing IX, (15 May 2002); doi: 10.1117/12.467839
Show Author Affiliations
Masahiro Akiba, Japan Science and Technology Corp. and Yamagata Univ. (Japan)
Kin Pui Chan, Japan Science and Technology Corp. and Yamagata Univ. (Japan)
Naohiro Tanno, Japan Science and Technology Corp. and Yamagata Univ. (Japan)


Published in SPIE Proceedings Vol. 4621:
Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing IX
Jose-Angel Conchello; Carol J. Cogswell; Tony Wilson, Editor(s)

© SPIE. Terms of Use
Back to Top