Measurement of chemical oxygen-iodine laser singlet oxygen generator parameter using Raman spectroscopy
Author(s): Weili Zhao; Fengting Sang; Liping Duo; Fang Chen; Yuelong Zhang; Benjie Fang
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Using a doubled Nd: YAG laser as a spontaneous vibrational Raman scattering source, and a single intensified CCD array at the exit of an imaging monochromator, the Raman scattering system is used to directly measure the concentrations of the O2(a1(Delta) ) and the O2((Chi) 3(Sigma) ) in the chemical oxygen-iodine laser singlet oxygen generator in real time. We present the results from the tests that conducted on a 0.1-mol singlet oxygen-iodine generator. With the current reported uncertainty of the Raman cross-section, the error in the yield measurement is calculated to be less than 8 percent.

Paper Details

Date Published: 6 May 2002
PDF: 6 pages
Proc. SPIE 4631, Gas and Chemical Lasers and Intense Beam Applications III, (6 May 2002); doi: 10.1117/12.465778
Show Author Affiliations
Weili Zhao, Dalian Institute of Chemical Physics (China)
Fengting Sang, Dalian Institute of Chemical Physics (China)
Liping Duo, Dalian Institute of Chemical Physics (China)
Fang Chen, Dalian Institute of Chemical Physics (China)
Yuelong Zhang, Dalian Institute of Chemical Physics (China)
Benjie Fang, Dalian Institute of Chemical Physics (China)


Published in SPIE Proceedings Vol. 4631:
Gas and Chemical Lasers and Intense Beam Applications III
Steven J. Davis; Michael C. Heaven, Editor(s)