Novel x-ray source for dual-energy subtraction angiography
Author(s): Alessandra Tuffanelli; Angelo Taibi; G. Baldazzi; Dante Bollini; Mirco Gombia; L. Ramello; Mauro Gambaccini
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In angiography practice an iodate contrast medium is injected in patient vessels with catheters. The absorption of x-rays raises immediately after the iodine K-edge energy. In digital subtraction angiography, two images are used, acquired before and after the injection of the contrast medium, respectively. The vessels morphology result from the difference of images so obtained. This technique involves a non-negligible risk of morbidity or mortality, due to high concentration of injected contrast agent. We are investigating a new source which produces two thin parallel quasi-monochromatic beams - having peak energies centered before and after the iodine K-edge energy, respectively - by using a conventional x-ray tube and a highly oriented pyrolytic graphite mosaic crystal. The polychromatic x-rays incident on the crystal are monochromatized by Bragg diffraction and split in two thin parallel beams, by means of a collimating system. These two beams impinge on the phantom simulating patient vessels and are detected with solid-state array detectors. The image results as difference between the remaining intensities of two beams. We report a preliminary study of the new technique performed both with theoretical stimulations and experimental measurements. Results of computer simulation give information about characteristics as size and quality of the quasi- monochromatic beams, that should be considered in detail to design a system dedicated to the clinical practice. Experimental measurements have been performed on a small- field detector in order to shows the enhancement of image contrast obtained with the application of the new technique.

Paper Details

Date Published: 3 May 2002
PDF: 9 pages
Proc. SPIE 4682, Medical Imaging 2002: Physics of Medical Imaging, (3 May 2002); doi: 10.1117/12.465572
Show Author Affiliations
Alessandra Tuffanelli, Univ. degli Studi di Ferrara and INFN (Italy)
Angelo Taibi, Univ. degli Studi di Ferrara and INFN (Italy)
G. Baldazzi, Univ. degli Studi di Bologna and INFN (Italy)
Dante Bollini, Univ. degli Studi di Bologna and INFN (Italy)
Mirco Gombia, Univ. degli Studi di Bologna and INFN (Italy)
L. Ramello, Univ. del Piemonte Orientale (Italy)
Mauro Gambaccini, Univ. degli Studi di Ferrara and INFN (Italy)

Published in SPIE Proceedings Vol. 4682:
Medical Imaging 2002: Physics of Medical Imaging
Larry E. Antonuk; Martin Joel Yaffe, Editor(s)

© SPIE. Terms of Use
Back to Top