The analysis of the polychromatic modulation transfer function (PMTF) for evaluating the image quality of the color LCD monitor is presented. The PMTF is easily calculated from the values of the MTF weighted by the overall spectral response of the system. To obtain the spectral response of the monitor, the chromaticity (x, y) and luminance are measured with a spectroradiometer. The variations of the luminance, chromaticity (x, y), and MTF of the color CRT and LCD monitors for different viewing angles are measured. We designed a synthetic equipment that could obtain the chromaticity (x, y), luminance, and MTF of the color monitor simultaneously. The experimental results of several color monitors made in Korea are presented.

Paper Details

Date Published: 20 September 2002
PDF: 9 pages
Proc. SPIE 4927, Optical Design and Testing, (20 September 2002); doi: 10.1117/12.464314
Show Author Affiliations
Jong Sup Song, Hannam Univ. (South Korea)
Yun Woo Lee, Korea Research Institute of Standards and Science (South Korea)
Hyun-Mo Cho, Korea Research Institute of Standards and Science (South Korea)
Seung Nam Park, Korea Research Institute of Standards and Science (South Korea)
In Won Lee, Korea Research Institute of Standards and Science (South Korea)
Jae Heung Jo, Hannam Univ. (South Korea)