Comparison of open- vs. closed-loop flexure compensation systems for two Keck optical imaging spectrographs: ESI and DEIMOS
Author(s): Robert I. Kibrick; Sandra M. Faber; Andrew C. Phillips; Molly McVeigh; David J. Cowley; Matthew V. Radovan; David Kirk Gilmore; Christopher A.F. Wright; Dean Tucker; De Clarke; Steven L. Allen
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Two recent Keck optical imaging spectrographs have been designed with active flexure compensation systems (FCS). These two instruments utilize different methods for implementing flexure compensation. The Echellette Spectrograph and Imager (ESI), commissioned at the Cassegrain focus of the Keck II Telescope in late 1999, employs an open-loop control strategy. It utilizes a mathematical model of gravitationally-induced flexure to periodically compute flexure corrections as a function of telescope position. Those corrections are then automatically applied to a tip/tilt collimator to stabilize the image on the detector. The DEep Imaging Multi-Object Spectrograph (DEIMOS), commissioned at the Nasmyth focus of Keck II in June 2002, implements a closed-loop control strategy. It utilizes a set of fiber-fed FCS light sources at the ends of the slitmask to produce a corresponding set of spots on a pair of FCS CCD detectors located on either side of the science CCD mosaic. During science exposures, the FCS detectors are read out several times per minute to measure any translational motion of the FCS spot images. Correction signals derived from these FCS images are used to drive active optical mechanisms which steer the spots back to their nominal positions, thus stabilizing the FCS spot images as well as those on the science mosaic. We compare the design, calibration, and operation of these two systems on the telescope. Long-term performance results will be provided for the ESI FCS, and preliminary results will be provided for the DEIMOS FCS.

Paper Details

Date Published: 7 March 2003
PDF: 14 pages
Proc. SPIE 4841, Instrument Design and Performance for Optical/Infrared Ground-based Telescopes, (7 March 2003); doi: 10.1117/12.461602
Show Author Affiliations
Robert I. Kibrick, UCO/Lick Observatory (United States)
Sandra M. Faber, UCO/Lick Observatory (United States)
Andrew C. Phillips, UCO/Lick Observatory (United States)
Molly McVeigh, UCO/Lick Observatory (United States)
David J. Cowley, UCO/Lick Observatory (United States)
Matthew V. Radovan, UCO/Lick Observatory (United States)
David Kirk Gilmore, UCO/Lick Observatory (United States)
Christopher A.F. Wright, UCO/Lick Observatory (United States)
Dean Tucker, UCO/Lick Observatory (United States)
De Clarke, UCO/Lick Observatory (United States)
Steven L. Allen, UCO/Lick Observatory (United States)


Published in SPIE Proceedings Vol. 4841:
Instrument Design and Performance for Optical/Infrared Ground-based Telescopes
Masanori Iye; Alan F. M. Moorwood, Editor(s)

© SPIE. Terms of Use
Back to Top