The FUSE detectors: on-orbit use and lessons learned
Author(s): David J. Sahnow
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The FUSE (Far Ultraviolet Spectroscopic Explorer) instrument includes two large-format microchannel plate detectors with double delay line anodes. The generally good detector performance has permitted the collection of scientific data with high spectral resolving power, and has enabled the observation of fainter objects than could be easily observed with previous missions in this wavelength range. As with any complex instrumentation, however, there have been numerous challenges which have arisen during the mission. We discuss the on-orbit performance of the FUSE detectors since launch, and describe some of the lessons learned. This includes a discussion of their operation on orbit and the effects that detector performance has had on the scientific data collected. The strategies taken to minimize the impact of detector anomalies on the data will also be discussed.

Paper Details

Date Published: 24 February 2003
PDF: 10 pages
Proc. SPIE 4854, Future EUV/UV and Visible Space Astrophysics Missions and Instrumentation, (24 February 2003); doi: 10.1117/12.459777
Show Author Affiliations
David J. Sahnow, Johns Hopkins Univ. (United States)

Published in SPIE Proceedings Vol. 4854:
Future EUV/UV and Visible Space Astrophysics Missions and Instrumentation
J. Chris Blades; Oswald H. W. Siegmund, Editor(s)