Share Email Print
cover

Proceedings Paper

Four-kiloframe 14-bit 128x128 digital imaging spectrometer
Author(s): William J. Mandl
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

A digital readout for a 128 by 128 MWIR focal plane using InSb detectors was developed for imaging spectrometry. There are a total of 16,384 oversample A/D converters on the chi p that provide a 14 bit linear data output at a nominal frame rate of 4,000 samples per second. An early prototype design was completed and tested without detectors and found to meet all requirements. A second iteration is in final hybrid assembly for demonstration where it will be mounted in a dewar with optics. The device is designed to work with a 3.3 volt power supply with on chip A/D power consumption of under 50 milliwatts. This technology was developed under a SBIR program sponsored by US Air Force, Arnold Air Force Base.

Paper Details

Date Published: 8 February 2002
PDF: 8 pages
Proc. SPIE 4486, Infrared Spaceborne Remote Sensing IX, (8 February 2002); doi: 10.1117/12.455120
Show Author Affiliations
William J. Mandl, Amain Electronics Co., Inc. (United States)


Published in SPIE Proceedings Vol. 4486:
Infrared Spaceborne Remote Sensing IX
Marija Strojnik; Bjorn F. Andresen, Editor(s)

© SPIE. Terms of Use