Theoretical study of variable function (cutting/coagulating) laser surgical system using continuous-wave 3 um, 2u m cascade Ho3+:ZBLAN fiber laser
Author(s): Kyota Naruse; Tsunenori Arai; Satoko Kawauchi; Tetsumi Sumiyoshi; Shoichi Kiyoshima; Miya Ishihara; Shunichi Sato; Makoto Kikuchi; Hitoshi Sekita; Minoru Obara
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We theoretically investigated variable-function (cutting/coagulating) characteristics of the continuous wave 3 μm, 2 μm cascade Ho3+:ZBLAN fiber laser using 3D heat-conduction calculation with finite element method. We have modified a commercial-available simulator in order to calculate heat conduction and thermal ablation process in soft tissue. In this calculation we considered specific heat rise due to the thermal denaturation of protein and volume shrinkage caused by temperature elevation. Beam profile, beam traveling speed, output power, and absorption coefficient were employed to describe the laser beam. The configuration of cutting groove and temperature distribution were calculated by varying the power ratio of the two wavelengths. Coagulation layer was defined as the region that was over 60°C for 1 second because we found that birefringence loss in porcine myocardium observed by a polarizing microscope occurred on this temperature history. When we increased the power ratio of 2 micrometers radiation to the total power of 0.9 W from 0% to 100% at the traveling speed of 0.5 mm/s, the incision depth decreased form 1.45 mm to 0.25 mm, while the coagulation layer thickness increased from 0.17 mm to 0.70 mm. We experimentally performed laser cutting on the same condition by our calculation using extracted porcine myocardium and compared this experimental results with the calculated results. We demonstrated that the incision depth and coagulation layer thickness estimated by our calculation indicated good agreement with the experimental results within 20% differences regarding the function variability by 3 μm/2 μm light mixing.

Paper Details

Date Published: 9 July 2001
PDF: 7 pages
Proc. SPIE 4257, Laser-Tissue Interaction XII: Photochemical, Photothermal, and Photomechanical, (9 July 2001); doi: 10.1117/12.434718
Show Author Affiliations
Kyota Naruse, Keio Univ. (Japan)
Tsunenori Arai, National Defense Medical College (Japan)
Satoko Kawauchi, National Defense Medical College (Japan)
Tetsumi Sumiyoshi, Cyber Laser Inc. (Japan)
Shoichi Kiyoshima, Computational Mechanics Inc. (Japan)
Miya Ishihara, National Defense Medical College (Japan)
Shunichi Sato, National Defense Medical College Research Institute (Japan)
Makoto Kikuchi, National Defense Medical College (Japan)
Hitoshi Sekita, Cyber Laser Inc. (Japan)
Minoru Obara, Keio Univ. (Japan)

Published in SPIE Proceedings Vol. 4257:
Laser-Tissue Interaction XII: Photochemical, Photothermal, and Photomechanical
Donald Dean Duncan; Peter C. Johnson; Donald Dean Duncan; Steven L. Jacques; Peter C. Johnson, Editor(s)

© SPIE. Terms of Use
Back to Top