NDE of adhesive joints and riveted structures with lock-in thermography methods
Author(s): Thomas Zweschper; Alexander Dillenz; Gerhard Busse
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Elastic waves sent into the component propagate inside the sample until they are converted into heat. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected elastic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by lock-in thermography synchronized to the frequency of amplitude modulation. This way ultrasound lock-in thermography allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. Measurements were performed on various kinds of mechanical joints. The results of our feasibility study indicate that both optical (OLT) and ultrasound exited lock-in thermography (ULT) are reliable tools for the rapid identification of damaged riveted structures. We demonstrate that one can locate a screw joint or a riveting which provide only a reduced stress. Investigations on airplane components were performed which confirmed the applicability of lock-in thermography for remote maintenance inspection within a few minutes.

Paper Details

Date Published: 23 March 2001
PDF: 7 pages
Proc. SPIE 4360, Thermosense XXIII, (23 March 2001); doi: 10.1117/12.421041
Show Author Affiliations
Thomas Zweschper, Univ. of Stuttgart (Germany)
Alexander Dillenz, Univ. of Stuttgart (Germany)
Gerhard Busse, Univ. of Stuttgart (Germany)


Published in SPIE Proceedings Vol. 4360:
Thermosense XXIII
Andres E. Rozlosnik; Ralph B. Dinwiddie, Editor(s)

© SPIE. Terms of Use
Back to Top