Paper Abstract

New type mist singlet oxygen generator (Mist-SOG) for the chemical oxygen-iodine laser (COIL) has been developed. This SOG is devoted to make the liquid recirculation unnecessary with the complete reaction through a single pass of basic hydrogen peroxide (BHP). 75% of Cl2 utilization and 76% of O2(1Æ) yield were obtained with Cl2 molar flow rate of 3.0 mmol/s. H2O2 utilization in the BHP was achieved as high as 12.3%. This value is about 24 times larger than that obtained by the liquid-jet SOG.

Paper Details

Date Published: 25 January 2001
PDF: 4 pages
Proc. SPIE 4184, XIII International Symposium on Gas Flow and Chemical Lasers and High-Power Laser Conference, (25 January 2001); doi: 10.1117/12.414023
Show Author Affiliations
Shigeki Muto, Tokai Univ. (Japan)
Takanori Kawano, Tokai Univ. (Japan)
Shoji Takeishi, Tokai Univ. (Japan)
Masamori Endo, Tokai Univ. (Japan)
Kenzo Nanri, Tokai Univ. (Japan)
Shuzaburo Takeda, Tokai Univ. (Japan)
Tomoo Fujioka, Tokai Univ. (Japan)