Share Email Print
cover

Proceedings Paper

Laser alignment system used for coaxiality measurement of large-scale holes
Author(s): Naiguang Lu; Wenyi Den; Bixi Yan; Qingshan Chen; Guozhong Liu
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

A single mode fiber (SMF) pigtailed laser diode alignment system used for coaxiality measurement of large scale holes is studied. The drift of angle of laser beam is restricted obviously by mode restriction of single mode fiber. The stability of laser reference line is the order of 1.5 x 10-6. It can be used in measurements of position and form errors of large scale workpieces.

Paper Details

Date Published: 10 October 2000
PDF: 4 pages
Proc. SPIE 4222, Process Control and Inspection for Industry, (10 October 2000); doi: 10.1117/12.403915
Show Author Affiliations
Naiguang Lu, Beijing Institute of Machinery (China)
Wenyi Den, Beijing Institute of Machinery (China)
Bixi Yan, Beijing Institute of Machinery (China)
Qingshan Chen, Beijing Institute of Machinery (China)
Guozhong Liu, Beijing Institute of Machinery (China)