Share Email Print
cover

Proceedings Paper

Effect of storage life and drive signals on the reliability of the Sandia Microengine
Author(s): Chad B. O'Neal; Ajay P. Malshe; William P. Eaton
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In this study, the parameters affecting operational and nonoperational reliability of the Sandia Microengine were investigated. It was found that using a non-outgassing die attach material greatly improves storage life. The minimum force required to drive the microengines initially decreased from a much higher voltage to settle in at around 1250 V2 for all devices tested. Drive signal parameters were optimzed for individual engines and the resulting device lifetimes were found to be marginally better that when average values were used (1.2x106 cycles compared to 1.0x106 cycles). There was no correlation between the value of the lumped parameter kr/a and lifetime found, however the longest living engines used a kr/a of around 1000 V2. ues. Optimized drive signal lifetimes were found to be a factor of two higher than when sinewave drive signals were used (5x105 compared to 1.2x106),indicating the advantage of using optimizzed drive signals, but not the two order of magnitude in lifetime that was desired.

Paper Details

Date Published: 10 August 2000
PDF: 10 pages
Proc. SPIE 4180, MEMS Reliability for Critical Applications, (10 August 2000); doi: 10.1117/12.395701
Show Author Affiliations
Chad B. O'Neal, Univ. of Arkansas (United States)
Ajay P. Malshe, Univ. of Arkansas (United States)
William P. Eaton, Sandia National Labs. (United States)


Published in SPIE Proceedings Vol. 4180:
MEMS Reliability for Critical Applications
Russell A. Lawton, Editor(s)

© SPIE. Terms of Use