Paper Abstract

We have designed, fabricated, tested and modeled a first generation small area test structure for MEMS fracture studies by electrostatic rather than mechanical probing. Because of its small area, this device has potential applications as a lot monitor of strength of fatigue of the MEMS structural material. By matching deflection versus applied voltage data to a 3D model of the test structure, we develop high confidence that the local stresses achieved in the gage section are greater than 1 GPa. Brittle failure of the polycrystalline silicon was observed.

Paper Details

Date Published: 3 September 1999
PDF: 7 pages
Proc. SPIE 3875, Materials and Device Characterization in Micromachining II, (3 September 1999); doi: 10.1117/12.360459
Show Author Affiliations
Maarten P. de Boer, Sandia National Labs. (United States)
Brian D. Jensen, Sandia National Labs. (United States)
Fernando Bitsie, Sandia National Labs. (United States)