Share Email Print
cover

Proceedings Paper

Calculational modeling of the Luch facility high-power amplifier pumping and pulse amplification
Author(s): V. A. Eroshenko; Sergey G. Garanin; Gennadi A. Kirillov; Gennady G. Kochemasov; V. A. Krotov; Stanislav A. Sukharev
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

Results of computational modeling of 'Luch' facility output amplifier module pumping by Monte-Carlo method is described as well as the results of calculations of short pulse amplification in 4-pass amplifier of this facility. The aim of calculations was study of stored energy space distribution homogeneity, optimization of amplifier configuration and investigation of output pulse profile sensitivity to input pulse from variations and value of small signal gain.

Paper Details

Date Published: 23 July 1999
PDF: 5 pages
Proc. SPIE 3492, Third International Conference on Solid State Lasers for Application to Inertial Confinement Fusion, (23 July 1999); doi: 10.1117/12.354252
Show Author Affiliations
V. A. Eroshenko, Russian Federal Nuclear Ctr. (Russia)
Sergey G. Garanin, Russian Federal Nuclear Ctr. (Russia)
Gennadi A. Kirillov, Russian Federal Nuclear Ctr. (Russia)
Gennady G. Kochemasov, Russian Federal Nuclear Ctr. (Russia)
V. A. Krotov, Russian Federal Nuclear Ctr. (Russia)
Stanislav A. Sukharev, Russian Federal Nuclear Ctr. (Russia)


Published in SPIE Proceedings Vol. 3492:
Third International Conference on Solid State Lasers for Application to Inertial Confinement Fusion
W. Howard Lowdermilk, Editor(s)

© SPIE. Terms of Use
Back to Top