Paper Abstract

Coherent effects in passive centimeter and millimeter wave emission used to detect landmines is investigated. The work concentrates on the modeling of the radiation temperatures of buried metal and plastic plates. A two interface model, which uses the dielectric constants of the media, is used to predict the radiation temperatures. Conclusions are that the use of coherence effects may complement the standard passive radiometry techniques for the detection of buried metal and plastic. This technique could extend the useful bandwidth, over which a system may operate, by a factor of two to three beyond that of standard radiometry.

Paper Details

Date Published: 14 July 1999
PDF: 7 pages
Proc. SPIE 3703, Passive Millimeter-Wave Imaging Technology III, (14 July 1999); doi: 10.1117/12.352996
Show Author Affiliations
Neil Anthony Salmon, Defence Evaluation and Research Agency Malvern (United Kingdom)