Paper Abstract

The JPEG compression algorithm was tested on a set of 529 chest radiographs that had been digitized at a spatial resolution of 100 micrometer and contrast sensitivity of 12 bits. Images were compressed using five fixed 'psychovisual' quantization tables which produced average compression ratios in the range 15:1 to 61:1, and were then printed onto film. Six experienced radiologists read all cases from the laser printed film, in each of the five compressed modes as well as in the non-compressed mode. For comparison purposes, observers also read the same cases with reduced pixel resolutions of 200 micrometer and 400 micrometer. The specific task involved detecting masses, pneumothoraces, interstitial disease, alveolar infiltrates and rib fractures. Over the range of compression ratios tested, for images digitized at 100 micrometer, we were unable to demonstrate any statistically significant decrease (p greater than 0.05) in observer performance as measured by ROC techniques. However, the observers' subjective assessments of image quality did decrease significantly as image resolution was reduced and suggested a decreasing, but nonsignificant, trend as the compression ratio was increased. The seeming discrepancy between our failure to detect a reduction in observer performance, and other published studies, is likely due to: (1) the higher resolution at which we digitized our images; (2) the higher signal-to-noise ratio of our digitized films versus typical CR images; and (3) our particular choice of an optimized quantization scheme.

Paper Details

Date Published: 24 May 1999
PDF: 6 pages
Proc. SPIE 3663, Medical Imaging 1999: Image Perception and Performance, (24 May 1999); doi: 10.1117/12.349627
Show Author Affiliations
Walter F. Good, Univ. of Pittsburgh School of Medicine (United States)
Glenn S. Maitz, Univ. of Pittsburgh School of Medicine (United States)
Jill L. King, Univ. of Pittsburgh School of Medicine (United States)
Rose C. Gennari, Univ. of Pittsburgh School of Medicine (United States)
David Gur, Univ. of Pittsburgh School of Medicine (United States)


Published in SPIE Proceedings Vol. 3663:
Medical Imaging 1999: Image Perception and Performance
Elizabeth A. Krupinski, Editor(s)

© SPIE. Terms of Use
Back to Top