We have developed a full field optical coherence microscopy (OCM) system operating at several frames per second. Depth ranging capability is compared between OCM and scanning confocal microscopy by imaging a test chart imbedded in 10 percent intralipid and imaging an onion. For sufficiently dense scattering, OCM was able to resolve test chart features and onion structures which were not detectable using confocal imaging alone.

Paper Details

Date Published: 30 April 1999
PDF: 9 pages
Proc. SPIE 3598, Coherence Domain Optical Methods in Biomedical Science and Clinical Applications III, (30 April 1999); doi: 10.1117/12.347491