Share Email Print
cover

Proceedings Paper

Near-infrared spectroscopy for LPG quality control
Author(s): James D. Ryan; Paul C. Russell; Gordon R. Jones; C. A. Gerrard; D. Strachan
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The analysis of the composition of liquefied petroleum gases is currently carried out by gas chromatography. This method is accurate, but is expensive and it is not practical for use in a low cost, field portable instrument. It has been shown that sufficient information can be obtained from the near infrared absorption spectra for the components of LPG to be distinguished. Two instruments are described: a novel device based on a number of low cost infrared light emitting diodes with a single detector, and a more conventional filter wheel based device. Experimental results indicate that an infrared system may be used to provide a robust and cost effective method of quality control of LPG products.

Paper Details

Date Published: 23 February 1999
PDF: 8 pages
Proc. SPIE 3540, Chemical, Biochemical, and Environmental Fiber Sensors X, (23 February 1999); doi: 10.1117/12.339780
Show Author Affiliations
James D. Ryan, Univ. of Liverpool (United Kingdom)
Paul C. Russell, Univ. of Liverpool (United Kingdom)
Gordon R. Jones, Univ. of Liverpool (United Kingdom)
C. A. Gerrard, Shell Research Ltd. (United Kingdom)
D. Strachan, Shell Research Ltd. (United Kingdom)