Share Email Print
cover

Proceedings Paper

Testing near-infrared spectrophotometry using a liquid neonatal head phantom
Author(s): Martin Wolf; Oskar Baenziger; Matthias Keel; Vera Dietz; Kurt von Siebenthal; Hans Ulrich Bucher
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We constructed a liquid phantom, which mimics the neonatal head for testing near infrared spectrophotometry instruments. It consists of a spherical, 3.5 mm thick layer of silicone rubber simulating skin and bone and acts as container for a liquid solution with IntralipidTM, 60 micrometers ol/l haemoglobin and yeast. The IntralipidTM concentration was varied to test the influence of scattering on haemoglobin concentrations and tissue oxygenation determined by the Critikon 2020. The solution was oxygenated using pure oxygen and then deoxygenated by the yeast. For the instruments algorithm, we found with increasing scattering (0.5%, 1%, 1.5% and 2% IntralipidTM concentration) an increasing offset added to the oxy- (56.7, 90.8, 112.5, 145.2 micrometers ol/l respectively) and deoxyhaemoglobin (25.4, 44.3, 58.5, 65.9 micrometers ol/l) concentration causing a decreasing range (41.3, 31.3, 25.0, 22.2%) of the tissue oxygen saturation reading. However, concentration changes were quantified correctly independently of the scattering level. For an other algorithm based on the analytical solution the offsets were smaller: oxyhaemoglobin 12.2, 34.0, 53.2, 88.8 micrometers ol/l and deoxyhaemoglobin 1.6, 11.2, 22.2, 28.1 micrometers ol/l. The range of the tissue oxygen saturation reading was higher: 71.3, 55.5, 45.7, 39.4%. However, concentration changes were not quantified correctly and depended on scattering. This study demonstrates the need to develop algorithms, which take into consideration the anatomical structures.

Paper Details

Date Published: 30 December 1998
PDF: 8 pages
Proc. SPIE 3566, Photon Propagation in Tissues IV, (30 December 1998); doi: 10.1117/12.334354
Show Author Affiliations
Martin Wolf, Univ. Hospital/Zurich (Switzerland)
Oskar Baenziger, Univ. Hospital/Zurich (Switzerland)
Matthias Keel, Univ. Hospital/Zurich (Switzerland)
Vera Dietz, Univ. Hospital/Zurich (Switzerland)
Kurt von Siebenthal, Univ. Hospital/Zurich (Switzerland)
Hans Ulrich Bucher, Univ. Hospital/Zurich (Switzerland)


Published in SPIE Proceedings Vol. 3566:
Photon Propagation in Tissues IV
David A. Benaron; Britton Chance; Marco Ferrari; Matthias Kohl-Bareis, Editor(s)

© SPIE. Terms of Use
Back to Top