In this article, we present a laser far-field CCD diagnostic device, which consists of optical system with (Phi) 250 mm aperture, the CCD image receive system connecting with a computer and a single pulse synchronous trigger system. The collected images are processed and displayed in real time by computer. A quasi-ideal plane wave at 1060 nm is used to test the characters of this diagnostic device. The experimental result shows that size of focal spot encompassing 70% laser energy is about 2.5 times of diffraction limit. The device has been successfully applied to high power laser facility. According to the practical measurement, the far-field divergence angle is less than 14 times of diffraction limit when output of high power laser facility is 200 J each beam.

Paper Details

Date Published: 29 October 1998
PDF: 5 pages
Proc. SPIE 3429, Current Developments in Optical Design and Engineering VII, (29 October 1998); doi: 10.1117/12.328560
Show Author Affiliations
Tingting Zhi, Shanghai Institute of Optics and Fine Mechanics (China)
Kuixi Huang, Shanghai Institute of Optics and Fine Mechanics (China)
Mingyi Ling, Shanghai Institute of Optics and Fine Mechanics (China)
Zunqi Lin, Shanghai Institute of Optics and Fine Mechanics (China)
Yuguang Xu, Shanghai Institute of Optics and Fine Mechanics (China)


Published in SPIE Proceedings Vol. 3429:
Current Developments in Optical Design and Engineering VII
Alson E. Hatheway; Robert E. Fischer; Malachy McConnell; Lawrence M. Germann; Lawrence M. Germann; Alson E. Hatheway; Malachy McConnell; Warren J. Smith, Editor(s)

© SPIE. Terms of Use
Back to Top