Share Email Print
cover

Proceedings Paper

Application of optical fiber sensors on the power dam of Luzzone
Author(s): Rolf Broennimann; Philipp M. Nellen; Peter Anderegg; Urs J. Sennhauser
Format Member Price Non-Member Price
PDF $17.00 $21.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The hydro-electric power dam of Luzzone in Switzerland has been heightened by 17 m to 225 m. Distributed fiber optical sensors, based on wavelength multiplexed Bragg gratings, have been embedded in the concrete to monitor temperature and strain evolution. The sensors were designed to make them suitable for embedding and operation in this harsh environment. Data taken during curing and the first year afterwards are presented.

Paper Details

Date Published: 29 September 1998
PDF: 6 pages
Proc. SPIE 3407, International Conference on Applied Optical Metrology, (29 September 1998); doi: 10.1117/12.323344
Show Author Affiliations
Rolf Broennimann, Swiss Federal Labs. for Materials Testing and Research (Switzerland)
Philipp M. Nellen, Swiss Federal Labs. for Materials Testing and Research (Switzerland)
Peter Anderegg, Swiss Federal Labs. for Materials Testing and Research (Switzerland)
Urs J. Sennhauser, Swiss Federal Labs. for Materials Testing and Research (Switzerland)


Published in SPIE Proceedings Vol. 3407:
International Conference on Applied Optical Metrology
Pramod Kumar Rastogi; Ferenc Gyimesi, Editor(s)

© SPIE. Terms of Use