Paper Abstract

Superconducting YBCO microbridge has been proven with high sensitivity and fast response speed. We have prepared successfully the High Tc superconducting IR detectors of this composition. When the temperature of blackbody is 500K the performance of detector is: D* equals 5.06 X 1010 cmHz1/zW-1; NEP equals 2.8 X 10-14WHz-1/2; R equals 8.87 X 104VW-1 and this performance can be held stable in two years. Using the detector we have done experiment at bolometric response from 300K to 600K and spectral response from 1 micrometers to 1224 micrometers . Experiment results show that the detector is nearing practical use and is the best detector for wide band.

Paper Details

Date Published: 11 August 1998
PDF: 6 pages
Proc. SPIE 3553, Detectors, Focal Plane Arrays, and Imaging Devices II, (11 August 1998); doi: 10.1117/12.318071
Show Author Affiliations
Dan Li, Nanjing Univ. of Science and Technology (China)
Jianxun Zhou, Nanjing Univ. of Science and Technology (China)
Guo Zhen Li, Kunming Institute of Physics (China)


Published in SPIE Proceedings Vol. 3553:
Detectors, Focal Plane Arrays, and Imaging Devices II
Pingzhi Liang; Marc Wigdor; William G. D. Frederick, Editor(s)

© SPIE. Terms of Use