Share Email Print
cover

Proceedings Paper

VLT Unit Telescope suitability for interferometry: first results from acceptance tests on subsystems
Author(s): Bertrand Koehler
Format Member Price Non-Member Price
PDF $14.40 $18.00

Paper Abstract

The very large telescope (VLT) project includes an interferometric mode which consists in combining coherently the four 8-m telescopes as well as a number of 1.8-m Auxiliary Telescopes to achieve milli-arcsecond angular resolution. This mode, referred to as the VLT Interferometer (VLTI), imposes specific requirements on the whole observatory and, in particular, on the telescopes. One of these specific requirements is the very high stability required on the optical path length (OPL) at the level of a few tens of nanometers. To verify the feasibility of achieving this requirement, a number of studies have been preformed in the past years with encouraging results. In the last months, the readiness of major VLT sub-systems permitted to start the verification of these conclusions by test. This paper presents these first results on OPL stability obtained during acceptance testing on several subsystems of the VLT 8-m Unit Telescopes.

Paper Details

Date Published: 24 July 1998
PDF: 11 pages
Proc. SPIE 3350, Astronomical Interferometry, (24 July 1998); doi: 10.1117/12.317104
Show Author Affiliations
Bertrand Koehler, European Southern Observatory (Germany)


Published in SPIE Proceedings Vol. 3350:
Astronomical Interferometry
Robert D. Reasenberg, Editor(s)

© SPIE. Terms of Use
Back to Top