Real-time diagnostic imaging with a novel x-ray detector with multiple screen-CCD sensors
Author(s): Cornelis H. Slump; Pieter W. van Dijk; Geert-Jan Laanstra; Henny Kuipers; Mark A. Boer; Alex G. J. Nijmeijer; Rudolf Kemner; Henk J. Meulenbrugge; Ruud M. Snoeren
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In reference 1 we have presented the principle of an X-ray detector based upon a screen coupled to an array of multiple CCD sensors. In reference 2 we focus on the characterization of the image quality: resolution (MTF) and noise behavior in the overlap area. Simple (and cheap) low F# lenses likely show distortion which means that not all imaged pixels have the same magnification. This may affect resolution. Lenses with (some) barrel distortion have the benefit of less vignetting. The correction of distortion in combination with a rotation adjustment requires interpolation. Interpolation affects the noise properties so care must be taken in order to avoid that the noise characterization of the reconstructed image mosaic i.e. the noise texture becomes spatially non uniform. We present an analysis of the influence of lens distortion and interpolation in cases of small rotation correction on the image mosaic. The image processing appears not to diminish the image quality provided the processing parameters are set correctly. The calibration of the imaging mosaic geometry is crucial. We therefore present a robust extraction algorithm. In this paper our main interest is on MTF and quantum noise properties. The lab prototype hardware is designed such (cubic spline interpolation) that also the lens distortion can be compensated. For this purpose ASICs are designed by the company AEMICS. This enables relative cheap optical components with low F# and a short building length. We have obtained and will present radiographic exposures of static phantoms.

Paper Details

Date Published: 24 July 1998
PDF: 12 pages
Proc. SPIE 3336, Medical Imaging 1998: Physics of Medical Imaging, (24 July 1998); doi: 10.1117/12.317042
Show Author Affiliations
Cornelis H. Slump, Univ. of Twente (Netherlands)
Pieter W. van Dijk, Univ. of Twente (Netherlands)
Geert-Jan Laanstra, Univ. of Twente (Netherlands)
Henny Kuipers, Univ. of Twente (Netherlands)
Mark A. Boer, AEMICS (Netherlands)
Alex G. J. Nijmeijer, AEMICS (Netherlands)
Rudolf Kemner, Philips Medical Systems (Netherlands)
Henk J. Meulenbrugge, Philips Medical Systems (Netherlands)
Ruud M. Snoeren, Philips Medical Systems (Netherlands)


Published in SPIE Proceedings Vol. 3336:
Medical Imaging 1998: Physics of Medical Imaging
James T. Dobbins; John M. Boone, Editor(s)

© SPIE. Terms of Use
Back to Top