Fast inspection of radius, wall thickness, eccentricity and ovality at the end of high precision tubes: TRUDE 60-28 in the production
Author(s): Wolfram Kleuver; Juergen Weber; Detlef Justen; Klaus Hartmann
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

In this paper we would like to present a new idea for measuring high precision tubes with an accuracy of +/- 10 micrometers . The most interesting values of the tubes are wall thickness, diameter, eccentricity and so on. The cycle of measuring is not more than 5 seconds inclusive the complete tube handling. The preferred sensor concept is the triangulation technique with a matched sensor head.

Paper Details

Date Published: 25 September 1997
PDF: 9 pages
Proc. SPIE 3100, Sensors, Sensor Systems, and Sensor Data Processing, (25 September 1997); doi: 10.1117/12.287761
Show Author Affiliations
Wolfram Kleuver, Univ. Siegen (Germany)
Juergen Weber, Univ. Siegen (Germany)
Detlef Justen, Univ. Siegen (Germany)
Klaus Hartmann, Univ. Siegen (Germany)