Share Email Print
cover

Proceedings Paper

Neutron-induced photon response of an NE213 scintillation detector
Author(s): T. Novotny; Sigmund Guldbakke; Horst Klein
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

The response of an NE213 scintillator has been determined for photons induced in the detector assembly by neutrons with energies between 1 MeV and 16 MeV. Coupled MCNP4A/EGS4 Monte Carlo simulations were compared and adjusted to experimental data. The complete set of response matrices for neutrons, photons and neutron induced photons was then used to determined the spectral neutron and photon fluence of 239Pu/13C and 241Am/9Be sources.

Paper Details

Date Published: 27 February 1997
PDF: 4 pages
Proc. SPIE 2867, International Conference Neutrons in Research and Industry, (27 February 1997); doi: 10.1117/12.267867
Show Author Affiliations
T. Novotny, Czech Metrological Institute (Czech Republic)
Sigmund Guldbakke, Physikalisch-Technische Bundesanstalt (Germany)
Horst Klein, Physikalisch-Technische Bundesanstalt (Germany)


Published in SPIE Proceedings Vol. 2867:
International Conference Neutrons in Research and Industry
George Vourvopoulos, Editor(s)

© SPIE. Terms of Use