Share Email Print
cover

Proceedings Paper

Radioscopy and computed tomography for failure analysis using microfocus x ray
Author(s): Richard H. Bossi; Dan A. Cross; Reid A. Mickelsen
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

X-ray microfocus radioscopy and computed tomography (CT) offer detailed information on the internal assembly and material condition of objects under failure analysis investigation. Using advanced systems for the acquisition of radioscopic and CT images, failure analysis investigations are improved in technical accuracy at a reduced schedule and cost over alternative approaches. A versatile microfocus radioscopic system with CT capability has been successfully implemented as a standard tool in the Boeing Defense and Space Group Failure Analysis Laboratory. Using this tool, studies of electronic, electromechanical and composite material items have been performed. Such a system can pay for itself within two years through higher productivity of the laboratory, increased laboratory value to the company and resolution of critical problems whose worth far exceeds the value of the equipment. The microfocus x-ray source provides projection magnification images that exceed the sensitivity to fine detail that can be obtained with conventional film radiography. Radioscopy, which provides real-time images on a video monitor, allows objects to be readily manipulated and oriented for optimum x-ray evaluation, or monitored during dynamic processes to check performance. Combined with an accurate manipulating stage and data acquisition system x-ray measurements can be used for CT image reconstruction. The CT image provides a cross sectional view of the interior of an object without the interference of superposition of features found in conventional radiography. Accurate dimensional measurements and material constituent identification are possible from the CT images. By taking multiple, contiguous CT slices entire 3D data files can be generated of objects.

Paper Details

Date Published: 15 November 1996
PDF: 8 pages
Proc. SPIE 2944, Nondestructive Evaluation of Materials and Composites, (15 November 1996); doi: 10.1117/12.259063
Show Author Affiliations
Richard H. Bossi, Boeing Defense & Space Group (United States)
Dan A. Cross, Boeing Defense & Space Group (United States)
Reid A. Mickelsen, Boeing Defense & Space Group (United States)


Published in SPIE Proceedings Vol. 2944:
Nondestructive Evaluation of Materials and Composites
Steven R. Doctor; Carol A. Nove; George Y. Baaklini, Editor(s)

© SPIE. Terms of Use
Back to Top