Multi-contrast imaging on dual-source photon-counting-detector (PCD) CT
Author(s): Shengzhen Tao; Kishore Rajendran; Cynthia H. McCollough; Shuai Leng
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Photon-counting-detector (PCD) CT can provide multiple energy bin data sets and allows single-acquisition, multiple-contrast-injection imaging using materials such as iodine, gadolinium and bismuth. However, due to technical limitations, PCDs can suffer from compromised energy-resolving capability, which degrades multicontrast imaging performance. In this work, we investigate the use of a dual-source (DS)-PCD system architecture with additional beam filtration to improve spectral separation among energy bin data sets, and quantify its performance for multi-contrast imaging. Experiments were performed using a CT phantom including various concentrations of iodine (I), gadolinium (Gd) and bismuth (Bi). The DS-PCD architecture was emulated by scanning the same phantom twice on a single-source (SS) PCD-CT with two different tube potentials: 80 kV (energy thresholds = 25/50 keV), and 140 kV (energy thresholds = 25/90 keV) with a 0.4-mm tin filter. We further compared material decomposition performance using the proposed DS-PCD approach with that of the current SS-PCD approach. For the SS-PCD, chess mode with 4 energy bins was used, with energy thresholds of 25/50/75/90 keV to resolve the K-edges of Gd and Bi. The mean energies of the four energy bins in SS-PCD were 72/76/93/109 keV, while those of the four energy bins using DS-PCD were 57/64/88/111 keV, denoting a better spectral separation using DS-PCD. The material quantification root mean square error (RMSE) was reduced from 4.5/3.3/1.2 mg/mL for iodine/Gd/Bi using SS-PCD, to 1.4/1.2/1.1 mg/mL using DS-PCD. These results demonstrate that the DS-PCD can improve multi-contrast imaging performance compared to a SS-PCD acquisition.

Paper Details

Date Published: 1 March 2019
PDF: 7 pages
Proc. SPIE 10948, Medical Imaging 2019: Physics of Medical Imaging, 109484L (1 March 2019); doi: 10.1117/12.2513497
Show Author Affiliations
Shengzhen Tao, Mayo Clinic (United States)
Kishore Rajendran, Mayo Clinic (United States)
Cynthia H. McCollough, Mayo Clinic (United States)
Shuai Leng, Mayo Clinic (United States)


Published in SPIE Proceedings Vol. 10948:
Medical Imaging 2019: Physics of Medical Imaging
Taly Gilat Schmidt; Guang-Hong Chen; Hilde Bosmans, Editor(s)

© SPIE. Terms of Use
Back to Top