3D ultrasound biomicroscopy (3D-UBM) imaging and automated 3D assessment of the iridocorneal angle for glaucoma patients
Author(s): Hao Wu; Ahmed Tahseen Minhaz; Rich Helms; Duriye Damla Sevgi; Taocheng Yu; Faruk Orge M.D.; David L. Wilson
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

We created a new high resolution (50-MHz) three-dimensional ultrasound biomicroscopy (3D-UBM) imaging system and applied it to the measurement of iridoconeal angle, an important biomarker for glaucoma patients. Glaucoma, a leading cause of blindness, often results from poor drainage of the fluid from the eye through structures located at the iridiocorneal angle. Measurement of the angle has important implications for predicting the course of the disease and determining treatment strategies. An angle measured at a particular location with conventional 2D-UBM can be biased due to tilt in the hand-held probe. We created a 3D-UBM system by automatically scanning a 2D UBM with a precision translating stage. Using 3D-UBM, we typically acqure several hundred 2D images to create a high-resolution volume of the anterior chamber of the eye. Image pre-processing included intensity based frame-to-frame alignment to reduce effects of eye motion, 3D noise reduction, and multi-planar reformatting to create rotational views along the optic-axis with the pupil at the center, thereby giving views suitable for measurement of the iridiocorneal angle. Anterior chambers were segmented using a semantic-segmentation convolutional neural network, which gave folded “leave-one-eye-out” accuracy of 98.04%±0.01%, sensitivity of 90.97%±0.02%, specificity of 98.91%±0.01%, and Dice coefficient of 0.91±0.04. Using segmentations, iridiocorneal angles were automatically estimated using a modification of the semi-automated trabecular- iris-angle method (TIA) for each of ∼360 rotational views. Automated measurements were compared to those made by four ophthalmologist readers in eight images from two eyes. In these images, an insignificant difference (p = 0.996) was shown between readers and automated results.

Paper Details

Date Published: 15 March 2019
PDF: 8 pages
Proc. SPIE 10955, Medical Imaging 2019: Ultrasonic Imaging and Tomography, 109550U (15 March 2019); doi: 10.1117/12.2513072
Show Author Affiliations
Hao Wu, Case Western Reserve Univ. (United States)
Ahmed Tahseen Minhaz, Case Western Reserve Univ. (United States)
Rich Helms, Univ. Hospitals Rainbow Babies & Children's Hospital (United States)
Duriye Damla Sevgi, Univ. Hospitals Rainbow Babies & Children's Hospital (United States)
Taocheng Yu, Case Western Reserve Univ. (United States)
Faruk Orge M.D., Univ. Hospitals Rainbow Babies & Children's Hospital (United States)
David L. Wilson, Case Western Reserve Univ. (United States)


Published in SPIE Proceedings Vol. 10955:
Medical Imaging 2019: Ultrasonic Imaging and Tomography
Brett C. Byram; Nicole V. Ruiter, Editor(s)

© SPIE. Terms of Use
Back to Top