Share Email Print
cover

Proceedings Paper • new

Handheld OCT-A using spectrally encoded coherence tomography and reflectometry (Conference Presentation)
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Optical coherence tomographic angiography (OCT-A) technologies have been primarily demonstrated on slit-lamp systems, which preclude imaging in infants, bedridden patients, or patients who are otherwise unable to be imaged upright. Current-generation OCT-A requires densely-sampled volumetric datasets for high vascular resolution imaging, but bulk motion artifacts, resulting from saccades or eye drifts, often distort anatomic features during long acquisitions. Here, we demonstrate handheld motion-artifact corrected OCT-A using spectrally encoded coherence tomography and reflectometry (SECTR). SECTR has advantageous over previously demonstrated handheld ophthalmic imagers by acquiring spatiotemporally co-registered, high-speed en face images of the retinal fundus using spectrally encoded reflectometry (SER) concurrently with OCT. The orthogonal priority acquisition axes of SER and OCT enables volumetric registration and motion-artifact compensation. We have incorporated several optomechanical improvements including novel snap-fit lens mounts for reduced size and weight and improved optical stability over our previous design. Additionally, we developed a method for reducing back reflections from a double-clad fiber by fusion-splicing a no-core fiber segment with a predefined geometry. Lastly, we demonstrate in vivo human OCT-A imaging of the optic nerve head and fovea. OCT and OCT-A images were motion-corrected using complementary motion information extracted from en face SER and cross-sectional OCT images. Here, OCT-A volumetric datasets were densely-sampled in small regions-of-interest within a large SER field-of-view to achieve high vascular resolution OCT-A while maintaining sufficient fiducials within SER images for motion registration. We believe our probe will enable point-of-care functional ophthalmic imaging.

Paper Details

Date Published: 13 March 2019
PDF
Proc. SPIE 10858, Ophthalmic Technologies XXIX, 108580Z (13 March 2019); doi: 10.1117/12.2510340
Show Author Affiliations
Joseph D. Malone, Vanderbilt Univ. (United States)
Mohamed T. El-Haddad, Vanderbilt Univ. (United States)
Yuankai Tao, Vanderbilt Univ. (United States)


Published in SPIE Proceedings Vol. 10858:
Ophthalmic Technologies XXIX
Fabrice Manns; Per G. Söderberg; Arthur Ho, Editor(s)

© SPIE. Terms of Use
Back to Top