Share Email Print
cover

Proceedings Paper • new

Development of a scanning photoacoustic tomography system for tumor margin assessment in breast conserving surgery
Author(s): Lawrence C. M. Yip; Parsa Omidi; Ivan Kosik; Astrid Chamson-Reig; Muriel Brackstone; Jeffrey J. L. Carson
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Photoacoustic tomography (PAT) has excellent sensitivity for hemoglobin and lipids, which make up much of human breast tissue. Our group has focused on intraoperative PAT applied to tissues obtained during breast-conserving surgery (BCS). In BCS, the tumor is excised with a margin of healthy tissue to ensure tumor removal. Margin detection can be difficult and re-excision surgeries are required in 10 to 25% of cases. Our first-generation intraoperative PAT system was capable of 3D imaging specimens up to 11 cm in diameter and several centimeters thick. The system used a semi-circular ring of low frequency transducers, resulting in a 2.5 mm spatial resolution. The current objective is to improve spatial resolution using higher frequency transducers. An array was constructed with 41 circular transducers positioned on two concentric circular rungs with a single point of focus. An optical window at the center allowed illumination. The array was tested with imaging phantoms consisting of written words on a clear plastic bag, 108 µm polyester monofilament arranged as parallel lines with spacing varying from 1 mm to 8 mm, and finally with porcine tissues. The array was positioned above and perpendicular to the imaging area and raster scanned. Signal averaging was implemented, and images were reconstructed with universal back projection. Image analysis demonstrated a 400 μm spatial resolution, but with low penetration depth and low sensitivity. Results suggest the transducers could improve spatial resolution of the first-generation intraoperative PAT system by 6-fold.

Paper Details

Date Published: 26 February 2019
PDF: 8 pages
Proc. SPIE 10868, Advanced Biomedical and Clinical Diagnostic and Surgical Guidance Systems XVII, 108680M (26 February 2019); doi: 10.1117/12.2507587
Show Author Affiliations
Lawrence C. M. Yip, Lawson Health Research Institute (Canada)
Western Univ. (Canada)
Parsa Omidi, Lawson Health Research Institute (Canada)
Western Univ. (Canada)
Ivan Kosik, Lawson Health Research Institute (Canada)
Astrid Chamson-Reig, Lawson Health Research Institute (Canada)
Muriel Brackstone, Lawson Health Research Institute (Canada)
Western Univ. (Canada)
Jeffrey J. L. Carson, Lawson Health Research Institute (Canada)
Western Univ. (Canada)


Published in SPIE Proceedings Vol. 10868:
Advanced Biomedical and Clinical Diagnostic and Surgical Guidance Systems XVII
Anita Mahadevan-Jansen, Editor(s)