Performance of a position-sensitive gamma-ray detector unit based on CsI(T1) bars with photodiode readout
Author(s): Claudio Labanti; Ezio Caroli; Anthony J. Dean; Guido Di Cocco; G. Ferrandi; K. J. Grant; Christopher J. Hall; E. M. Quadrini; Elio Rossi; Filomena Schiavone; Aldo Spizzichino; Bruce Miles Swinyard; Alessandro Traci; Gabriele E. Villa
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Analytical considerations and test results bearing on the performance of a CsI(Tl) scintillating crystal coupled with a photodiode when used as a gamma-ray spectrometer are addressed. Laboratory test results on a number of CsI(Tl) bars with different sizes, diffusive coatings, and preamplifier designs are presented. A suitable event selection electronic logic design is shown which reduces the effect of noise on the count rate while retaining the desired energy threshold.

Paper Details

Date Published: 1 November 1990
PDF: 12 pages
Proc. SPIE 1344, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy, (1 November 1990); doi: 10.1117/12.23234
Show Author Affiliations
Claudio Labanti, ITESRE/CNR (Italy)
Ezio Caroli, ITESRE/CNR (Italy)
Anthony J. Dean, Univ. of Southampton (United Kingdom)
Guido Di Cocco, ITESRE/CNR (Italy)
G. Ferrandi, IFCTR/CNR (Italy)
K. J. Grant, Univ. of Southampton (United Kingdom)
Christopher J. Hall, Univ. of Southampton (United Kingdom)
E. M. Quadrini, IFCTR/CNR (Italy)
Elio Rossi, ITESRE/CNR (Italy)
Filomena Schiavone, ITESRE/CNR (Italy)
Aldo Spizzichino, ITESRE/CNR (Italy)
Bruce Miles Swinyard, Rutherford Appleton Lab. (United Kingdom)
Alessandro Traci, ITESRE/CNR (Italy)
Gabriele E. Villa, IFCTR/CNR (Italy)

Published in SPIE Proceedings Vol. 1344:
EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy
Oswald H. W. Siegmund; Hugh S. Hudson, Editor(s)

© SPIE. Terms of Use
Back to Top