Share Email Print
cover

Proceedings Paper

Salicylic acid (SA) detection using bi-enzyme microfluidic electrochemical sensor
Format Member Price Non-Member Price
PDF $14.40 $18.00
cover GOOD NEWS! Your organization subscribes to the SPIE Digital Library. You may be able to download this paper for free. Check Access

Paper Abstract

Salicylic Acid (SA) is a phyto-hormone involved in the regulation of induced plant defense mechanisms, primarily against biotic stresses. Various methods have been reported for detecting SA. The electrochemical methods offer economical, portable, and accurate concentration measurement of bio-chemicals like SA. Electrochemical biosensors often require modification of the working electrode (WE) with specific materials to functionalize it with bio-molecules, needed for target analyte recognition. The proposed biosensor provides a unique methodology of selectively coating the inter-digital electrodes (IDE) and further applying the method to develop a biosensor to detect SA. The electrodes are fabricated using a novel deposition process termed as, Capillary action assisted deposition (CAAD) which consists of IDEs fabricated in the form of small finger-like channels connected to a wider main channel. The drop-casted sample automatically flows from the main channel into the fine fingers under the effect of capillary action. The sensor includes a 3-electrode system arranged in a 3-D geometry, forming an integrated microfluidic channel for analyte solution flow. The WE is selectively coated with, first, Graphene oxide (GO) and next, the bi-enzyme Salicylate Hydroxylase (SH) and Tyrosinase (TYR) recipe using the proposed CAAD process. The bi-enzyme exhibits selectivity towards SA and the proposed sensor shows the detection range of 0.5 μ𝑀 to 64 μ𝑀. The electrochemical reactions are characterized by Chrono-amperometry (CA) and shows the sensitivity of 34.4 μA cm-2 per decade change in SA concentration (in μ𝑀). To the best of our knowledge, the proposed bi-enzyme system in a microfluidic device for SA sensing is the first of its kind.

Paper Details

Date Published: 14 May 2018
PDF: 7 pages
Proc. SPIE 10662, Smart Biomedical and Physiological Sensor Technology XV, 106620K (14 May 2018); doi: 10.1117/12.2305124
Show Author Affiliations
Bhuwan Kashyap, Iowa State Univ. of Science and Technology (United States)
Ratnesh Kumar, Iowa State Univ. of Science and Technology (United States)


Published in SPIE Proceedings Vol. 10662:
Smart Biomedical and Physiological Sensor Technology XV
Brian M. Cullum; Douglas Kiehl; Eric S. McLamore, Editor(s)

© SPIE. Terms of Use
Back to Top